Professional Data Recovery Laboratory in Pakistan

Server Data Recovery

Recovery for failed servers and RAID-backed storage, working through the controller, array and volume layers in order rather than rebuilding first and assessing later.

Server storage failures are rarely a single-drive problem. A hardware or software RAID controller, several member drives, and the file system or database sitting on top of them can each fail independently or in combination. DiskAnalyst treats server recovery as a layered problem — first understanding the RAID and controller context, then the individual drives, then the data structures built on top of them — rather than assuming a standard single-drive procedure applies.

Server racks in a data centre

Common Causes of Failure

RAID Controller Failure

A failed or faulty controller card can make an otherwise healthy array of drives appear offline or unreadable.

Multiple Drive Failure

When more member drives fail than the RAID level can tolerate, the array goes offline even though some drives may still be partially readable.

Failed Rebuild

Starting a rebuild on an already-degraded array is one of the most common causes of further, more serious data loss.

File System / Volume Corruption

NTFS, ReFS, EXT4, XFS or LVM structures can become corrupted even when the underlying array itself is intact.

Logical or Accidental Deletion

A volume, partition or set of files deleted or reformatted on a server, with the array hardware itself unaffected.

What We Handle

  • Windows Server and Linux server storage
  • Hardware RAID controllers (commonly encountered environments include Dell PERC, HPE Smart Array and LSI/Broadcom-based controllers) and software RAID
  • Servers commonly encountered include Dell PowerEdge, HPE ProLiant, Lenovo and Supermicro platforms
  • NTFS, ReFS, EXT4 and XFS volumes, and LVM-managed storage
  • Database files and virtual disks stored on server volumes
  • Multi-drive arrays with more than one failed or degraded member

Common Signs & Failure Scenarios

Array shows as offline or degraded
Server will not boot
Controller reports a critical/failed status
Volume shows as RAW or unformatted
A database will not mount
One or more member drives clicking or not spinning

Our Recovery Approach

  1. 1

    Preserve the Original Drives

    Member drives are not written to and no rebuild is started before the array and drives have been assessed.

  2. 2

    Identify RAID Context

    We determine the RAID level, controller type, and original member-drive order before doing anything else.

  3. 3

    Image Unstable Members

    Any unstable member drive is imaged individually in a controlled environment rather than read directly and repeatedly.

  4. 4

    Reconstruct the Array

    The array is reconstructed virtually from the images or healthy drives, without altering the original media.

  5. 5

    Recover Volumes and Files

    The file system, volumes, database files and virtual disks are recovered from the reconstructed array and verified.

Important: What Not To Do

  • Do not force a RAID rebuild on a degraded array before it has been assessed.
  • Do not reinitialize or reformat the array or any member drive.
  • Do not run chkdsk, fsck or similar repair tools on a volume that is not mounting normally.
  • Do not swap drive order or replace a failed member without recording the original positions first.

Devices & Configurations We Cover

Rack Server
Tower Server
RAID Controller
NAS / SAN Storage

Frequently Asked Questions

Ready to Start Your Recovery Case?

Tell us what happened to your device and we'll advise on the right next step.