Professional Data Recovery Laboratory in Pakistan

RAID Data Recovery

Business-grade recovery for degraded, failed and misconfigured RAID arrays — hardware and software, single or multiple member failure.

RAID failures rarely involve a single point of failure. A degraded array, an interrupted rebuild, or a controller fault can all put stored data at risk, and the safest response is diagnosis before any further changes are made to the array. DiskAnalyst reconstructs array configuration and recovers data from the individual member drives in a controlled lab environment.

Multi-bay RAID storage enclosure

Common Causes of Failure

Multiple Drive Failure

More than one member drive failing, or failing close together, can take an array below its fault-tolerance threshold.

Failed or Interrupted Rebuild

A rebuild that fails partway through can leave an array in an inconsistent state, sometimes affecting data beyond the drive that was being rebuilt.

Controller / Configuration Loss

Damage to a hardware controller, or loss of its configuration, can make an otherwise healthy set of drives appear as an unreadable array.

Degraded Array

An array running in degraded mode has lost its redundancy — a further single failure can take the entire array offline.

Logical / File-System Corruption

The underlying array can be structurally intact while the file system built on top of it is corrupted or inaccessible.

What We Handle

  • RAID 0, 1, 5, 6 and 10 arrays
  • Failed or interrupted RAID rebuilds
  • Multiple simultaneous drive failures
  • Degraded or offline arrays
  • Hardware and software RAID controllers
  • Business and server RAID storage

Common Signs & Failure Scenarios

Array shows as degraded or offline
Controller reports a fault
Rebuild failed or stalled
One or more drives dropped from array
Array not recognized after power loss
Multiple drives failing simultaneously

Our Recovery Approach

  1. 1

    Member Imaging

    Each surviving member drive is imaged individually before any reconstruction is attempted, so the original drives are not put at further risk.

  2. 2

    Array Parameter Analysis

    We determine disk order, stripe or block size, parity rotation and offsets from the imaged data rather than assuming the original controller settings.

  3. 3

    Virtual Reconstruction

    The array is reconstructed virtually from the member images, without writing back to the original drives.

  4. 4

    File-System Recovery

    Once the array structure is reconstructed, the file system on top of it is recovered and your files are extracted.

Important: What Not To Do

  • Do not initialize the array.
  • Do not create a new RAID in place of the failed one.
  • Do not force a rebuild without understanding the condition of each member drive.
  • Do not change the order of the drives.
  • Label each drive before removing it from the array or enclosure.
  • Do not allow automatic repair or rebuild tools to write to the member disks.

Devices & Configurations We Cover

RAID 0
RAID 1
RAID 5
RAID 6
RAID 10
Hardware RAID
Software RAID
Server Arrays

Frequently Asked Questions

Ready to Start Your Recovery Case?

Tell us what happened to your device and we'll advise on the right next step.

Submit a Case →